Circuit-Breakers > Thermal-Push-Button-Circuit-Breakers
Carling CMB Thermal Push Button Circuit Breakers - Low Amp
Carling CMB Series thermal circuit breakers are single-pole, push-to-reset breakers with a compact design that protects your equipment and applications. The push button breakers utilize a simple and precise design that features few moving parts. The design allows the thermal circuit breaker to be extremely cost-effective while remaining durable and reliable. A push button breaker is a great choice for reliable circuit protection that also needs resistance against shock and vibration. Each push button breaker provides a consistent trip point over temperatures ranging from -10°C to +60°C. Select a low amp or high amp thermal circuit breaker for your household and commercial applications, transportation equipment, marine, audio-visual, medical, and other power supplies. The quick connect design of the push button breaker makes installation simple and provides an easy to use thermal circuit breaker for your application. Get the perfect combination of easy to use, highly protective, and cost-effective protection with a push button circuit breaker from Del City.
- Rating: 125-250 VAC, 32VDC
- Operating Temperature: -10°C to 60°C
- Dielectric Strength: 2500 VAC/1 Minute
- Interrupting Capacity: 2500 amps @ 32 VDC
- Insulation Resistance: 100M ohms
- Voltage Drop: < 0.25V
- Standards: UL, CUL, CSA, TUV, CE
- UL1500/ISO8846 for marine and ignition protection
- RoHS Compliant
W/O BOOT | W/ BOOT | BOOT ONLY | |||||||||||||||
Item | Description |
Price
|
Qty in
Package |
In Stock | Add to Cart | |||||||||||
70611 | Carling Technologies CMB-033-11D1B-W-A/03, 3 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70612 | Carling Technologies CMB-043-11D1B-W-A/04, 4 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70613 | Carling Technologies CMB-053-11D1B-W-A/05, 5 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70614 | Carling Technologies CMB-063-11D1B-W-A/06, 6 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70615 | Carling Technologies CMB-073-11D1B-W-A/07, 7 Amp CMB Series Push Button Circuit Breaker (1 MIN) (LIMITED QUANTITY) |
|
1 EA | ✓ | ||||||||||||
70616 | Carling Technologies CMB-083-11D1B-W-A/08, 8 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70608 | Carling Technologies CMB-153-11D1B-W-A/15, 15 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70606 | Carling Technologies CMB-203-11D1B-W-A/20, 20 Amp CMB Series Push Button Circuit Breaker (1 MIN) |
|
1 EA | ✓ |
Carling CMB Thermal Push Button Circuit Breakers - Low Amp with Boot
Carling CMB Series thermal circuit breakers are single-pole, push-to-reset breakers with a compact design that protects your equipment and applications. The push button breakers utilize a simple and precise design that features few moving parts. The design allows the thermal circuit breaker to be extremely cost-effective while remaining durable and reliable. A push button breaker is a great choice for reliable circuit protection that also needs resistance against shock and vibration. Each push button breaker provides a consistent trip point over temperatures ranging from -10°C to +60°C. Select a low amp or high amp thermal circuit breaker for your household and commercial applications, transportation equipment, marine, audio-visual, medical, and other power supplies. The quick connect design of the push button breaker makes installation simple and provides an easy to use thermal circuit breaker for your application. Get the perfect combination of easy to use, highly protective, and cost-effective protection with a push button circuit breaker from Del City.
- Rating: 125-250 VAC, 32VDC
- Operating Temperature: -10°C to 60°C
- Dielectric Strength: 2500 VAC/1 Minute
- Interrupting Capacity: 2500 amps @ 32 VDC
- Insulation Resistance: 100M ohms
- Voltage Drop: < 0.25V
- Standards: UL, CUL, CSA, TUV, CE
- UL1500/ISO8846 for marine and ignition protection
- RoHS Compliant
W/O BOOT | W/ BOOT | BOOT ONLY | |||||||||||||||
Item | Description |
Price
|
Qty in
Package |
In Stock | Add to Cart | |||||||||||
70618 | Carling Technologies CMB-043-11D5B-W-A/04, 4 Amp CMB Series Push Button Circuit Breaker w/ Boot (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70619 | Carling Technologies CMB-053-11D5B-W-A/05, 5 Amp CMB Series Push Button Circuit Breaker w/ Boot (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70620 | Carling Technologies CMB-063-11D5B-W-A/06, 6 Amp CMB Series Push Button Circuit Breaker w/ Boot (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70621 | Carling Technologies CMB-073-11D5B-W-A/07, 7 Amp CMB Series Push Button Circuit Breaker w/ Boot (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70622 | Carling Technologies CMB-083-11D5B-W-A/08, 8 Amp CMB Series Push Button Circuit Breaker w/ Boot (1 MIN) |
|
1 EA | ✓ | ||||||||||||
70607 | Carling Technologies CMB-153-11D5B-W-A/15, 15 Amp CMB Series Push Button Circuit Breaker with Boot (1 MIN) |
|
1 EA | ✓ |
Carling CMB Thermal Push Button Circuit Breakers Boot
Carling CMB Series thermal circuit breakers are single-pole, push-to-reset breakers with a compact design that protects your equipment and applications. The push button breakers utilize a simple and precise design that features few moving parts. The design allows the thermal circuit breaker to be extremely cost-effective while remaining durable and reliable. A push button breaker is a great choice for reliable circuit protection that also needs resistance against shock and vibration. Each push button breaker provides a consistent trip point over temperatures ranging from -10°C to +60°C. Select a low amp or high amp thermal circuit breaker for your household and commercial applications, transportation equipment, marine, audio-visual, medical, and other power supplies. The quick connect design of the push button breaker makes installation simple and provides an easy to use thermal circuit breaker for your application. Get the perfect combination of easy to use, highly protective, and cost-effective protection with a push button circuit breaker from Del City.
- Rating: 125-250 VAC, 32VDC
- Operating Temperature: -10°C to 60°C
- Dielectric Strength: 2500 VAC/1 Minute
- Interrupting Capacity: 2500 amps @ 32 VDC
- Insulation Resistance: 100M ohms
- Voltage Drop: < 0.25V
- Standards: UL, CUL, CSA, TUV, CE
- UL1500/ISO8846 for marine and ignition protection
- RoHS Compliant
W/O BOOT | W/ BOOT | BOOT ONLY | |||||||||||||||
Item | Description |
Price
|
Qty in
Package |
In Stock | Add to Cart | |||||||||||
70500 | Carling Technologies 8T1-E-115, Replacement Clear Boot for Push Button Circuit Breakers (1 MIN) |
|
1 EA | ✓ |